1, temperature range of hot water: room temperature
-95℃
2, control precision of hot water: set value±2℃
3, temperature range of cold water: 15℃-room temperature
(room temperature
>15℃)
4, control precision of cold water: set value±5℃
5, temperature evenness: ±1℃
6, temperaturedisplay precision: 0.1℃
7, pressure control range: 0.5-1.5Mpa
8, pressure control precision: set value±0.05Mpa
9, cycle time: 15min
10, exchange time: 1min
11, cycle time: 1-5000 times
12, Max pipe diameter: Φ63mm
13, test loop number: 1, 2, 3, 4, 5, 6
14, power: AC380V±10%
15, power : 30KW |