[Main technical conditions]
Application Temperature:-20-200
Application
Pressure:Inside Machine0.085MPa;Inside
stuff0.4MPa
heat
transmission coefficient:485Kcal/hm2C
Porcelain
layer withstanding voltage:20KV
Porcelain
layer thickness:0.8-1.8mm
Flange
flatness:0.3% DN
Flange
circular degree :0.4% DN
The Enamel
physical and chemical properties and the porcelain facing
appearance come up to HG2432-93 and Q/320281 ADA02--1996 specifications.
[Appearance Dimensions]
W-0.5 |
heat inter-changing area m2 |
middle-level number of panels / piece |
overall height H(mm) |
external diameter (mm) |
Weight kg |
1.5 |
2 |
670 |
700 |
230 |
2 |
3 |
760 |
700 |
270 |
2.5 |
4 |
850 |
700 |
320 |
3 |
5 |
950 |
700 |
360 |
3.5 |
6 |
1040 |
700 |
410 |
4 |
7 |
1130 |
700 |
450 |
4.5 |
8 |
1220 |
700 |
500 |
5 |
9 |
1320 |
700 |
550 |
6 |
11 |
1500 |
700 |
650 |
6.5 |
12 |
1600 |
700 |
700 |
7 |
13 |
1680 |
700 |
750 |
W-1 |
heat inter-changing area m2 |
middle-level number of panels / piece |
overall heightH (mm) |
external diameter (mm) |
Weight kg |
5 |
4 |
1000 |
960 |
580 |
6 |
5 |
1100 |
960 |
660 |
7 |
6 |
1200 |
960 |
740 |
8 |
7 |
1290 |
960 |
820 |
9 |
8 |
1380 |
960 |
900 |
10 |
9 |
1470 |
960 |
980 |
11 |
10 |
1560 |
960 |
1060 |
12 |
11 |
1650 |
960 |
1140 |
13 |
12 |
1740 |
960 |
1220 |
14 |
13 |
1830 |
960 |
1300 |
15 |
14 |
1920 |
960 |
1380 |
|
Picture Marks |
W-0.5 |
W-1 |
|
450mm |
660mm |
R |
220mm |
220mm |
D |
20mm |
22mm |
A |
medium entrance DN80 |
medium entrance DN100 |
B |
water pipes are connected by Ħ°DIĦħtube. |
|
[Properties]
The product consists of W-2 model and W-0.5 model. The condensation
area of W-0.5 model is cupped plate, each 0.5m2. And the equipment's
external diameter is 700mm.
The W-1 model cupped plate is 1m2 each and the equipment external
diameter is 960mm.
The detail specifications of 1.5-15m2 series are optional
according to the condensation number.
The product is small cubage and light with a compact structure.
The condensation of the thermal current can be achieved by
the antiphase flowing heat exchange of thermal current and
cooling water.
This product's condensation efficiency can be improved by
1-2 times, compared with the glass lining telescopefeed condensator
in same acreage and the carbon heat exchanger.
When the components damage appears, can partially renovate
or reduce the monolithic.
|