FPFAS513
Epoxy Anti-static Floor Finish
Intend
Uses
|
As antistatic finish, suited for floors or walls, which require
antistatic or anti-explosive coatings, such as
in electric factory, control room, computer
room, printing factory, spinning mill etc.
|
Product
Description
|
High solid and high build, epoxy floor paint, two components. The film
possesses abrasion resistance, antistatic
property, semi-gloss or high gloss. Some colors
can be made.
|
Product
Information
|
Volume
Solids
|
55-60%
|
Color
|
Black, Grey, green, blue, red, yellow etc.
Limited colors.
|
DFT
|
50-200µm, according to the surface condition.
|
Anti-static
Resistance
|
105-108Ω(ASTM F150-98)
|
Theoretical
Coverage
|
4.4 - 5.2 m2/Kg, based on dry film thickness of 100µm.
|
Application
Details
|
Mix
ration
|
A:
B = 5:1 (By weigh)
|
Method
of Application
|
Airless
Spray: Recommended.
Brush
or Roller: Suitable.
Air Spray: Recommended, thinning is
necessary.
|
Thinner
|
OUP
103
|
Cleaner
|
OUP
103
|
Pot Life
|
35℃: 2 hours;
25℃: 4 hours;
15℃: 6 hours
|
Drying Time
|
Substrate
Temperature
|
Touch
Dry
(h)
|
Hard
Dry
(h)
|
Completely
cure
(d)
|
Over
coating Interval
|
Minimum
|
Maximum
|
35℃
25℃
15℃
|
≤2
≤4
≤6
|
≤12
≤24
≤36
|
≤3
≤5
≤7
|
12
24
36
|
No
limitation
|
Storage
and Handling
|
Storage
|
Dry
and cool conditions, Storage Life: One year
|
Pack Size
|
A:
20 Kg in 20 litre container; B:
4 Kg in 4 litre container
|
Flash Point
|
>33℃
(Mixture, A and B)
|
Specific Gravity
|
1.05-1.15
Kg/L
|
Specification
and Surface Preparation |
Before application with this paint product, all cracks, joints,
protrudent and hollow spot on the floor should
be filled up and repaired correctly. And the
surface has been applied sealer and paved with
conductive copper film connecting ground, or
other conducting coatings (Such as conductive
filler or conductive intermediate coatings),
Thus the surface must be smooth clean and dry.
This product cannot cure fully at low temperature. The substrate
temperature should be maintained above 10℃ for good effect.
Must mix component A and B according to the practical quantity. Recommend
making this paint just before painting with it.
Should stir to even before application. It is
recommended to use the paint mixture up in pot
life in case it would cure and could not be
used.
After painting, may walk on the floor when the film is hard dry. It
cannot be used until it cures completely |
Safety
Precautions |
This product should be used in painting area by professional operators.
When painting, please refer to Product Data
Sheet and MSDS. Consult our company if consumers
could not completely understand the precautions
for safety and health when applying this
product.
This product is a kind of solvent-based paint. In order to avoid danger
or accident, minimal safety precautions, as
follow, should be done::
The paint
contains volatile solvent and is flammable. So
must keep away from sparks and open flames. No
smoking at application site. Effective
precautions (such as using explosion-proof
electrical equipments, no static electricity
accumulation or metal collision etc) also should
be done so as to avoid producing sparks. Flash
point of paint, mentioned above on Product Data
Sheet, is the lowest temperature at which
mixture of the volatile materials of paint can
ignite or explode with air, so we suggest
painting should be stopped above the temperature
of flash point.
Enough ventilation is
necessary at application site. In order to
remove any danger of explosion, must keep the
ratio of gas to air is less than 10%, the
minimum explosive limit in general. Therefore,
200m3 of ventilation quantity per 1Kg
solvent (according to the solvent) is necessary.
Protect skin and eyes, and avoid touching with paints (Recommend to wear
working clothes, gloves, eye protection, face
masks, barrier creams and so on). If paint gets
in touch with skin, wash fully with a large
amount of fresh water and soap or appropriate
commercial cleaner. In case of eyes being
contaminated, rinse with fresh water for 10min
at least and give medical treatment immediately.
Recommend face guard with ventilation pipe for the sake of no absorption
of paint fog and harmful solvent gas, especially
in badly ventilated conditions.
Handle empty containers with care and do not bring about environmental
contamination..
NOTICE: If consumers haven't taken effective safety precautions (Refer to the
specifications), our company will NOT be
responsible for any accident. |
|
|
|
|