FPP502
Epoxy Sealer
Intend
Uses
|
Used to treat the surface of cement or concrete floor to be applied. When
the substrate is painted with it, a surface with
excellent adhesion to subsequent coat, which is
also impermeable and easy to clean, should be
gotten. Especially suitable for compact
substrates as connecting layer, such
high-strength cement or concrete floor, treated
terrazzo or marble surface. Also act as sealer
to cover substrate before painting with
solvent-based coatings for exterior wall.
|
Product
Description
|
Low viscosity. When the substrate is treated with this product, the
character of sealing-off and adhesion strength
of composite coats to the substrate has been
both reinforced.
|
Product
Information
|
Volume
Solids
|
50%-75%, basing on the requirements of customers
|
Color
|
Light yellow, transparent
|
DFT
|
Infiltrative,
infiltrate depth is depends on the substrate
conditions.
|
Theoretical
Coverage
|
30-100μm, depending on the
conditions of substrate, volume solids and the
number of coats.
|
Application
Details
|
Mix
ration
|
A:
B = 4:1 (By weigh)
|
Method
of Application
|
Brush
or Roller:
Recommended
|
Thinner
|
OUP
103
|
Cleaner
|
OUP
103
|
Pot Life
|
35℃-4h;25℃-6h;15℃-8h
|
Drying Time
|
Substrate
Temperature
|
Touch
Dry
(Min)
|
Hard
Dry
(h)
|
Over
coating Interval
|
Minimum
|
Maximum
|
35℃
25℃
15℃
|
≤15
≤30
≤45
|
≤16
≤24
≤36
|
8
12
24
|
3d
5d
7d
|
Storage
and Handling
|
Storage
|
Dry
and cool conditions, Storage Life: One year
|
Pack Size
|
A:
16 Kg in 20 litre container; B:
4 Kg in 4 litre container
|
Flash Point
|
>23℃
(Mixture, A and B)
|
Specific Gravity
|
0.95-1.05
Kg/L
|
Specification
and Surface Preparation |
Please consult our company about how to apply the floor paint.
If new floor is to be painted, the application should not start unless its construction was completed at least 20 days ago and water content of the substrate should be less than 8%.
Before application with this paint product, all cracks, joints, protrudent and hollow spots on the floor should be filled up and repaired correctly.Must mix component A and B according to the practical necessary quantity.
Recommend making this paint just before painting with it. Should stir to even before application. It should be used up in its pot life in case it would cure and could not be
used.
If the substrate is highly porous, recoat with this primer sealer some times so that the substrate should be sealed up, in case pinholes or bubbles would take place after the next
coat.
May paint the next coat after the film is hard dry. |
Safety
Precautions |
This product should be used in painting area by professional operators. When painting, please refer to Product Data Sheet and MSDS. Consult our company if consumers could not completely understand the precautions for safety and health when applying this product.This product is a kind of solvent-based paint. In order to avoid danger or accident, minimal safety precautions, as follow, should be done:The paint contains volatile solvent and is flammable. So must keep away from sparks and open flames. No smoking at application site. Effective precautions (such as using explosion-proof electrical equipments, no static electricity accumulation or metal collision etc) also should be done so as to avoid producing sparks. Flash point of paint, mentioned above on Product Data Sheet, is the lowest temperature at which mixture of the volatile materials of paint can ignite or explode with air, so we suggest painting should be stopped above the temperature of flash point.Enough ventilation is necessary at application site. In order to remove any danger of explosion, must keep the ratio of gas to air is less than 10%, the minimum explosive limit in general. Therefore, 200m3 of ventilation quantity per 1Kg solvent (according to the solvent) is necessary.Protect skin and eyes, and avoid touching with paints (Recommend to wear working clothes, gloves, eye protection, face masks, barrier creams and so on). If paint gets in touch with skin, wash fully with a large amount of fresh water and soap or appropriate commercial cleaner. In case of eyes being contaminated, rinse with fresh water for 10min at least and give medical treatment immediately.Recommend face guard with ventilation pipe for the sake of no absorption of paint fog and harmful solvent gas, especially in badly ventilated conditions.Handle empty containers with care and do not bring about environmental contamination.NOTICE: If consumers haven't taken effective safety precautions (Refer to the specifications), our company will NOT be responsible for any accident. |
|
|
|
|