Elution machine
B. Automatic operation
According to the used washing procedures and refer to the computer controller instructions to prepare the washing program,then store the selected program No.,In the lock-open state select the program then start according to the program, the machine will automatically complete all the action by the program.
Suggestion: The operation of automatic procedures should be applied after have adequate hand washing experience.
(Washing materials can not be too less or more than calibration rated capacity)
IV. The problems should be take into consideration in operation
1. Compressed air pressure should be between 0.4-0.6Mpa, air Source Treatment should be promptly refueling and drainage, otherwise, the machine can not work properly.
2.Manual operation should stop a certain action, should repeated press this button.
3.If you use automatic procedures to complete the washing process, the washing effect is related to various factors, such as the quantity of the washing materials, size, type or the degree of dirty etc.
4. Please do not casually shorten a certain of action if automatic operation.
5. Either manually or automatically operation, when runs into the dehydration stage, within 60 seconds, you should carefully observe the shaking situation of the front door.
6. It is better to classified the washing materials, meanwhile, sheet and blanket and other large materials should be loose so as not to wound each other and influence the following actions.
7.When the machine is working, the operator should not leave the post to avoid accidents.
8. The user must install safety valve, pressure gauge and stop valve in steam pipe to maintain the balance of the pressure.
Attention
When dehydration, it should be high water level, otherwise, will influence the performance of the machine. Meanwhile, either manually or automatically, the high dehydration time should not more than 3 minutes, the high operation in long time will influence the life of the machine.
V. The input amount of the washing materials:
The processing of the machine as shown in the table below, the excess input will overload thus shorten the life of the machine; on the other hand, the input is too low, the machine is not easy to maintain balance, reduce the washing effect and wastes energy.
Suggestion:
XGQ15T------------10—20Kg/Time XGQ30T------------25—30Kg/Time XGQ80T------------65—80Kg/Time
XGQ50T------------40—50Kg/Time XGQ100T-----------80—100Kg/Time
| |
XGQ 15T |
XGQ 30T |
XGQ 50T |
XGQ 80T |
XGQ 100T |
|
XGQ 15T |
XGQ 30T |
XGQ 50T |
XGQ 80T |
XGQ 100 |
| Shirt0.22Kg |
68 |
136 |
227 |
363 |
454 |
Work clothes 0.55 Kg |
28 |
55 |
90 |
145 |
181 |
| White clothes 0.4 Kg |
38 |
75 |
125 |
200 |
250 |
Work pants 0.55 Kg |
30 |
60 |
100 |
160 |
200 |
| Sheet0.45 Kg |
34 |
67 |
111 |
177 |
222 |
Hand towel 0.02 Kg |
750 |
1500 |
2500 |
4000 |
5000 |
| Sheet pair 0.7 Kg |
22 |
43 |
71 |
114 |
142 |
Quilt cover 1.2 Kg |
13 |
25 |
41 |
67 |
83 |
| Bathrobe 0.5 Kg |
30 |
60 |
100 |
160 |
200 |
Blanket 3.0 Kg |
5 |
10 |
16 |
27 |
33 |
| Bath towel 0.4 Kg |
38 |
75 |
125 |
200 |
250 |
Tablecloth 0.7 Kg |
22 |
43 |
71 |
114 |
142 |
(There are differences in material, species of the washing materials, the above information just for general reference)
VI The maintenance of the machine
In order to guarantee your machine can maintain the best economic performance economic benefits, it is necessary to do some maintenance and repair of the machine in the daily use. Please do as the following points:
1. Once a month or use about 30 times inject grease lithium grease (3) to oil cup of the machine.
2. It is necessary to check the bearing, door hinge, motor block, connectors to ensure safety.
3. Regularly check whether the water port in bearing base is smooth to ensure that no water in bearing base and extend the life of the bearing.
4. Regularly check if the V-belt is loose, and regular tighten the V-belt.
5. Please periodically discharge water of the gas source processor, and promptly replenish 10 # machine oil to the lubricator.
6.It the machine adopts mechanical brake, regularly put lubricating oil in the brake to avoid harsh noise when braking.
VII General failure and exclusion
| |
Failure phenomenon |
Help failure analysis |
Remedy |
| 1 |
The water level is low, but can not input water |
1. The water level control tube electrode point has garbage, misleading.
2. The valve is not open.
3. The solenoid valve is damage. |
1. Remove the water level control tube, cleaning and re-install.
2. Check the air compressor 3. Check the solenoid valve. |
| 2 |
The dewater has been finished and over time, but there is not action when pressing stop/get clothes button. |
1.Solenoid valve control door sales burned out.
2. The door handle is locked tight. |
1、Check the solenoid valve.
2. Pulling the door handle. |
| 3 |
1. Can not heated:Water can not be heated, the light does not shine.
2.The light is bright but cannot be heated. |
1. Electrode of low water has waste, misleading.
2.The temperature of the computer is not set.3. Gas valve is not open. |
1.Remove the water level control tube, cleaning and re-install.
2.Set the temperature of the computer 3.Check the solenoid valve. |
| 4 |
The computer has signal but the actuator does not respond. |
1.Computer connector loose.
2.The computer's fuse burned out. |
1. Check the connectors.
2. Change the fuse. |
| 5 |
The computer has signal but the actuator does not respond. |
The implementation components have been damaged, the line from the computer to the actuator is blocked. |
Check the condition of the implementation components, and the voltage of the component-side. |
| 6 |
Valve is not activated |
1. The atmospheric pressure is not enough.
2. There are wastes in the valve.
3. Ring damage and leakage. |
1. Adjust the atmospheric pressure.
2. Remove the waste.
3. Change the ring. |
| 7 |
Roller rotation speed uneven or don't roll |
1. V-belt slipping.
2. Inverter has no output. |
1. Adjust the V-belt.
2. Check the inverter. |
| 8 |
Machine downtime has no brakes. |
1. Braking resistor is not working.2.The brake cylinder has no action. |
1. Check the rsistor.
2. Check the brake solenoid valve and cylinder. |
| 9 |
Uniform in good condition but with much vibration. |
Whether the damper is stuck. |
1.Repair.
2. Change. |
| 10 |
Can not drain |
The drain valve is damaged. |
1. Check the drainage cylinder.
2. Check the drain solenoid valve. |
VIII The failure demonstration of the computer controller
If there are failure in operation, it will displayed on the LCD screen, please maintain the machine refer to the failure catalog in computer controller, and ensure the normal operation of the machine. |