Main issues |
Causes |
Solution |
Unconformity between baker temperature and given temperature |
Wire issues between thermocouple and heater strip |
Periodically check |
Adjust temperature controller |
Adjust or change broken part |
Thermocouple and heater strip issues |
Change |
Unstable net voltage |
Check and adjust |
Invalid sealing,reducing valve,pressure relief system |
Check all air supplying system |
Air surging |
Check air producing or consumption system |
Low pressure of gas-fired |
Check air pressure |
Large output |
Contact baker factory |
Unreasonable ratio of gas and air |
Adjust |
Extinct pilot lamp |
Gas valve closed |
Open valve |
Relief valve turning on |
Check wire and controlling valve |
Inadequate gas pressure |
Refer to inflamer requirements |
Flame lighter broken |
1.Check,clearing,change flame lighter
2.Check mend or change flame lighter
3.Check mend or change inflaming transformer |
Pilot lamp setting issues |
Refer to factory's standard |
Not fully exhaust cycle |
Check exhausting time |
No igniting of main inflamer |
Main valve closed |
Open main valve |
Opening safety controlling system |
Check wire and relief valve whether open |
Closed showing valve |
Check,Change |
Flame overseeing signal issues |
Check and change signal system |
Inadequate gas pressure |
Refer to equipment index |
Fuel controlling pump issues |
Maintenance,change |
Air valve issues |
Check the setting and operation of air valve |
Broken switch |
Adjust |
Parts pollution |
Sundries in baker pollution |
Clearing baker |
Charry particle |
Adjust inflamer |
No electrifying of loop |
Mistaken earth |
Check wire and connection |
Fuse and circuit breaker issues |
Change insurance,check reason |
Little hot wind |
Check wind inductor |
Powder blown |
Intense air impact part |
Reduce air flowing volume |
Electrifying but no heating of infrared equipment |
Button interlock |
Check and mend circuit |
Interlock system |
Check and mend circuit |
Timing, temperature controlling trouble |
Mend broken part |
Thermocouple trouble |
Mend thermocouple |
Breaks of AC contactor |
Often check and mend |
Melting of AC contactor fuse |
Check and adjust system or change fuse type |
Wire trouble from control panel to heating unit |
Fasten touch point |
Not fully heating |
|
1, Check and adjust system or change fuse type
2, Often check and mend circuit |
Unit burned or partial broken |
Mend or change unit |
Wire trouble |
Fasten the touch point |
No starting of heater |
Preheating unit is not turning on |
Often check and mend circuit |
Fuse trouble |
Check and adjust system or change fuse type |
Pipeline valve closed |
Open |
Unreasonable air pressure |
Contact equipment factories |
Not fully heating |
Unreasonable air pressure |
Contact equipment factories |
Jam of Whiff |
Clearing |
Thermocouple trouble |
Refer to the index of factory |
Unobstructed pipeline or valve |
Check and mend |
Overheating |
Unreasonable air |
Choose proper air or change nozzle |
Too high air pressure |
Adjust |