Characteristics | Home>Products>Characteristics |
MnZn Ferrite Material Characteristics
Material Characteristics | Test condition | Unit | ZP40 | ZP3A | ZH-L5 | ZH-L7 | ZH-L10 | ZH-L12 |
initial magnetic permeability(μi) | 25°C,10KHz,100mV | - | 2300±25% | 3600±25% | 5000±25% | 7000±25% | 10000±25% | 12000±30% |
magnetic flux density(B) | 25°C,10KHz,1200A/m | mT | 510 | 480 | 410 | 430 | 380 | 390 |
residual magnetic flux density(Br) | 25°C | mT | 100 | 180 | 100 | / | / | / |
100°C | mT | 55 | / | / | / | / | / | |
coercive force(Hc) | 25°C | A/m | 14 | 16 | 6 | / | / | / |
100°C | A/m | 9 | / | / | / | / | / | |
power loss(Pv) | 100°C,25KHz:200mT | KW/m3 | / | 190 | / | / | / | / |
100°C,100KHz:200mT | KW/m3 | 420 | / | / | / | / | / | |
electrical resistivity(ρ) | DC,25°C | Ωm | 6.5 | 5 | 1 | 0.5 | 0.5 | 0.1 |
Curie temperature(TC) | - | °C | ≥220 | ≥200 | ≥150 | ≥150 | ≥125 | ≥125 |
density | - | Kg/m3 | 4800 | 4800 | 4800 | 4800 | 4900 | 4900 |
Note: The date in the table is typical value, excluding of customer special requirements. If there was any special requirement, please illustrate in order contract or agreement.