CMS |
CMS is a new kind of adsorbent developing from 1970,and is excellent carbon material without polarity.It can be used as separating nitrogen from air.TO compare with cryogenic, PSA has some advantages:the investment is lower,start-up time is short:the cost for Nitrogen is lower.PSA Nitrogen generators apply in chemical, electronic, food, medical, metal heat treatment ets. |
|
In dynamics,CMS has different adsorptive rate for oxygen and nitrogen. Before the adsorption balanced oxygen and other impurities are adsorbed by the MSC,allowing unabsorbed nitrogen to pass through the bed. |
|
Various physical and chemical properties
as well as technical indexes of carbon sieve
1.Diameter:1.3-1.8mm
2.Bulk Density:630-660g/l
3.Hardness:90-100N/granule |
|
AdsorbingCyde:2×58s |
Model |
Adsorbing Pressure
(MPa) |
N 2 Purity(%) |
N 2 Production
(L/h.kg) |
Recovery
(%) |
CMS-230 |
0.8 |
99.99 |
100 |
25 |
99.9 |
140 |
36 |
99.5 |
230 |
46 |
99.0 |
280 |
51 |
98.0 |
350 |
55 |
CMS-240 |
0.8 |
99.99 |
110 |
26 |
99.9 |
150 |
38 |
99.5 |
240 |
48 |
99.0 |
300 |
55 |
98.0 |
370 |
59 |
CMS-250 |
0.8 |
99.99 |
120 |
28 |
99.9 |
160 |
41 |
99.5 |
250 |
50 |
99.0 |
310 |
55 |
98.0 |
380 |
59 |
|
[ BACK ] |
|
|
|
|