Scale and Fouling Inhibitors
For Reverse Osmosis
C hemical
fouling, typically due to carbonate, sulphate, silica, Iron, occurs as a
result of the concentration of dissolved inorganic salts at the membrane
surface, as pure water flows through the membrane, if the ionic product of a
dissolved salt exceeds its solubility product then precipitation can occur,
leading to fouling of the membrane surface.
Historically,
mineral acids and polyphosphate were used to control deposition in both
brackish water and seawater operations, but neither were satisfactory in all
conditions. Mineral acids can present serious supply problems and safety
hazards to plant operators. The use of acid also requires accurate dosing and
control if scaling and corrosion problems are to be minimized. Sulphuric acid
can also contribute to sulphate scaling problems. Polyphosphate is not
considered to be completely effective against sulphate deposition.
TRISPE 1000
A multifunctional
anti-scalant/anti-flulant for reverse osmosis system is an effective carbonate
and sulphate inhibitor specially formulated for use in high ionic strength
waters.
Characters:
-
Certified to ANSI/NSF
standard 60 for use in reverse osmosis systems producing potable water.
-
Compatible with
organic ST coagulant and many other organic coagulants.
-
Approved and
certified for use with membrane manufacture.
-
Allows optimized
plant recovery without the need for softening.
-
Effectively controls
scales including calcium carbonate, calcium sulfate, barium sulfate, LSI of the
concentrate water is 2.78 no scaling.
-
Maintains cleaner
membrane surfaces by dispersing particulates.
-
Effective PH range in
feed waters is 5-9.
-
Compatible with feed
water that contain aluminum and iron oxides.
-
Product may be fed
neat or diluted.
Recommended operation limits of brine water parameters:
Silica: 200 ppm max.
LSI: 2.78 max.
Iron: 1ppm max.
Aluminium: 0.5ppm max.
Calcium sulphate: 8000 ppm max
TRISPE 1600
Antiscalant/ antifoulant for reverse osmosis system is a multifunctional
antiscalant, highly effective in preventing calcium sulphate scale formation on
membrane surfaces.
Characters:
-
Certified to ANSI/NSF standard 60 for use in reverse
osmosis systems producing potable water
-
Compatible with organic ST coagulant and many other
organic coagulants.
-
Approved and certified for use with membrane
manufacture
-
Allows optimized plant recovery without the need for
softening.
-
Effectively controls scales including calcium
sulfate, barium sulfate.
-
Effectively controls scales including calcium
carbonate, calcium carbonate, calcium fluoride and metal oxides scale formation.
-
Maintains cleaner membrane surfaces by dispersing
particulates.
-
Effective PH range in feed waters is 5-9.
-
Compatible with feed water that contain aluminum and
iron oxides.
Recommended operation limits of brine water parameters:
Silica: 200 ppm max.
LSI: 2.60 max.
Iron: 1ppm max.
Aluminium: 0.5ppm max.
Calcium sulphate: 10000 ppm max.
TRISPE 1700
Antiscalant/antifoulant for reverse osmosis system
is a multifunctional antiscalant, highly effective in preventing calcium
sulphate scale formation on membrane surfaces.
Characters:
-
Certified to ANSI/NSF standard 60 for use in
reverse osmosis systems producing potable water.
-
Compatible with organic ST coagulant and many
other organic coagulants.
-
Approved and certified for use with membrane
manufacture.
-
Allows optimized plant recovery without the need
for softening.
-
Effectively controls scales including calcium
phosphate scale formation.
-
Effectively controls soluble iron.
-
Maintains cleaner membrane surfaces by
dispersing particulates.
-
Effective Ph range in feed waters is 5-9.
-
Compatible with feed water that contain aluminum
and iron oxides.
Recommended operation limits of brine water parameters:
Silica: 240 ppm max.
LSI: 2.60 max.
Iron: 4ppm max.
Aluminium: 0.5ppm max.
Calcium sulphate: 7000 ppm max.
Calcium fluoride: 120ppm max
TRISPE 1800
Antiscalant/ antifoulant for reverse osmosis
system is a multifunctional antiscalant, highly effective in preventing silica
scale formation on membrane surfaces as well as controlling calcium carbonate,
strontium sulfate, barium sulfate, iron and calcium fluoride scale formation.
CHARACTERS:
- Certified to ANSI/NSF standard
60 for use in reverse osmosis systems producing potable water.
- Compatible with organic ST
coagulant and many other organic coagulants.
- Approved and certified for use
with membrane manufacture.
- Allows optimized plant recovery
without the need for softening.
- Effectively controls scales
silica scale formation (up to 400ppm) as well as controlling inorganic
scaling including calcium carbonate, calcium sulfate, barium sulfate.
- Maintains cleaner membrane
surfaces by dispersing particulates.
- Effective PH range in feed
water is 5-9.
- Compatible with feed water that
contain aluminum
Recommended operation limits of brine water parameters:
Silica: 400 ppm max.
LSI: 2~2.5 max.
Iron: 0.5ppm max.
Aluminium: 0.5ppm max.
|